Back to Membranes

Traspir Evo 300

Can be used as a Temporary Weather Protection Cladding to allow an early start on the internal linings. High UV stability, up to 9 months full exposure. Plus permanent exposure for partially open claddings with open joints up to 50mm wide and with up to 40% of the surface uncovered. Ideal for low pitched roofs.

Monolithic acrylic mix film, applied to polyester (PL) reinforcing layer.

High UV Stability

9 month resistance to UV rays with full exposure to radiation and no protection. High thermal resistance up to 120C.

LCA - Life Cycle Assessment

Sustainability study of all aspects related to the production, use and disposal of the product in accordance with EN ISO 140 44.

EPD - Environmental Product Declaration

Type III environmental declaration on the environmental impact in accordance with EN ISO 14025

AUS/NZ 4200.1 Class 4

Classified as a Class 4 vapour permeable membrane.

Reaction to Fire

.European classification according to EN 13501-1 indicating degree of combustibility, smoke density and dripping potential. The low values indicate low combustibility/self-extinguishing, no smoke, and no dripping potential.

High Mass, Non-Flamable, Thermal Stability
The ideal membrane for residential or commercial use in areas of climate extremes, partially open cladding, high UV exposure, and/or areas where operating temperatures exceed the standards.

Where can it be applied?

For use on external roof

Codes and Dimensions

codeexcodedescriptiontapeHxL[m]A[m2]
TTTEVO300D42524TRASPIR EVO 300 TTTT1.5 X 5075

Technical Specifications

propertystandardvalue
Mass per unit areaEN 1849-2300 g/m2
ThicknessEN 1849-20.5 mm
StraightnessEN 1848-2conforming
Water vapour transmission (Sd)EN 1931/EN ISO 125720.04 m
Maximum tensile fore MD/CDEN 12311-1320/200 N/50 mm
Elongation MD/MCEN 12311-130/35%
Resistance to tearing MD/MCEN 12310-1130 /140 N
Water-tightnessEN 1928class W1
Water columnEN 20811> 500 cm
UV stability with joints up to 50 mm wide with up to 40% of the surface uncovered EN 13859-1permanent
UV resistance without final claddingEN 13859-19 months
Temperature resistance--40/+120˚c
Reaction to fireEN 13501-1Class B-s1, d0
Resistance to penetration of airEN 12114<0.02 m3/m2h50pa
After ageing:--
• maximum tensile force MD/CDEN 13859-1310 / 190 N/50 mm
• water-tightnessEN 13859-1class w1
• elongation MD/CDEN 13859-128 / 33 %
Flexibility at low temperatureEN 1109-40C
Dimensional stabilityEN 1107-2< 1 %
Thermal conductivity (λ)-0.3 W/mK
Specific heat-1800 J/kgK
Density-approx. 600 kg/m3
Water vapour resistance factor (μ)-approx. 80
Recommended installation pitch->10 degrees
Driving rain testTU Berlinpassed
VOC emissions-0 % (class A+)
Joint strength EN 12317-2>280 N/50 mm